Precision Drill Press Vise 5 新建网页 1

Electromagnetic Directional Valve 110V

 

Note: If you are International customer out of USA, please contact with us for consulting the detailed shipping information. 

 

Introduction:

Installation position any
environment temperature(℃)
-30~+50(Minny rubber seal)
-20~+50(Rubber seal)
Weight Single solenoid valve kg 1.45
Single solenoid valve kg 1.95

Hydraulic data  

highest working pressure Oil mouthP.A.B MPa 31.5
Oil mouthT MPa 21(DC):16(AC)

When the work pressure more than allowed, the sign bit A, B valve must use T for drainage

Maximum flow L/min 80(DC):60(AC)
flow area Q model mm^2 About 6% of the nominal cross-sectional area
flow area W model mm^2 About 3% of the nominal cross-sectional area
hydraulic oil

1.Suitable for minny rubber seal and fluorine rubber seal

2.Only applicable to fluorine rubber seal

Mineral oil(HL,HLP)According to the DIN51:524

Rapid biodegradation oil According to the DIN24:568

HETG1);

HEPG;2);HEES;2

oil temperature range (℃) -30~+80(Minny rubber seal)

-20~+80(rubber seal)

Viscosity range mm2/s 2.8~500
oil cleanliness The highest oil pollution level by NASI639 recommend filter class 9

Minimum filtration precisionβ>75

Electrical data

Voltage data DC AC
power supply voltage V 12,24,48,110,220 110 220
Allow the voltage deviation % +10~-15 +10~-15
Loss of power W 30  
Keep the current A - 0.27(220V)
Starting current A - 0.72(220V)
Working system ED% 100 100
The reversing time ms 125~145 10~20
Reset the time ms 100~250 15~40
Switching frequency T/H <=15000 <=7200
Press DIN40050 protection grade IP65(AMP:IP66) (Deutsch:IP69K)
Allow the coil temperature rise (℃) 135 180

1.In the electrical link, the grounding protection line should be according to stipulations

2.Ac plastic commutation time close to dc, ac/dc type long reset time, and has randomness

 

 
Item# Description QTY Unit Note
230509 electromagnetic directional valve 1 Set