Product Overview
  The production of hidden denture by the hot press and automatic temperature control instrument composed of two parts, with automatic temperature control, automatic insulation and audio prompt function, is the implicit denture manufacturing equipment necessary.
First, the main technical parameters
Product Parameters
Package size: 22.4"x15.8"x13.4" (57x40x34cm)
Gross weight: 32KG(70.4lb)
Use power: 110V/60Hz
Power consumption: 400W
Product Features & Advantages
(1) Temperature setting of the automatic thermostat: Press '+' before turning on the power

'-' key to adjust the mechanical number, the temperature should be set between 282-288 ℃ (factory set before).

(2) Timing setting of the automatic thermostat: Press '+' '-' before turning on the power supply,

Key to set the time 's' for seconds 'M' for minutes 'H', the time is set to

8 points (factory set).

(3) connected to the machine's power cord and heating output line, thermocouple line by "+", "-" connected.

(4) sound prompt switch to "heating" side, press the "heating" switch, thermostat digital display for the ambient temperature. At this point began to heat up, the heater work properly.

(5) When the temperature reaches the set temperature, the buzzer prompts, hear the prompt after the audio prompt switch to the "timer switch" side. After loading the stealth glue into the top block, and then open the "timer switch" switch.

(6) 8 minutes later (factory settings) buzzer prompt again, hear the prompts, the rotation of the die-casting handle to die-casting to be completed, until the natural work done after the completion of Ling.

(7) thermostat reaches the set temperature after about 10 ℃ heating is normal.

Note: Due to the geographical altitude and the different seasons, so according to the actual situation set the heating temperature and holding time, such as finished color is too deep may be appropriate to set the set temperature and holding time, such as too shallow color can reduce the set temperature and holding time
Product Presentation & Details
https://buyyou.net/cbe/data/prd/021/150/15.jpg
 
https://buyyou.net/cbe/data/prd/021/150/16.jpg
 
https://buyyou.net/cbe/data/prd/021/150/17.jpg
 
https://buyyou.net/cbe/data/prd/021/150/18.jpg
 
https://buyyou.net/cbe/data/prd/021/150/9.jpg
 
https://buyyou.net/cbe/data/prd/021/150/11.jpg
 
https://buyyou.net/cbe/data/prd/021/150/12.jpg
Item Included
A set of 110V Dental Lab Flexible Denture Dentistry Invisible denture Injection Machine (021150)
无标题文档

About Us

Copyright techtongda365.com All Rights Reserved