8L 220V
Electric Pressurized Steam Sterilizer |
|
|
Generation:
Volume |
Voltage |
Weight |
Outside Space |
8L |
220V |
17.4lb/7.9kg |
14.2*14.2*11.8(inch)/36*36*30(cm) |
|
|
Advantage:
- Adopt the advanced
stainless steel 304, it is more durable
for acid and alkaline.
- The appliance could be heated by
light fire and electric power, which
would be convenient of using.
- The machine adopt
the wrought iron flanges to strengthen,
which guarantee the safety and stabilization.
- Deflating when overpressure:
0.145-0.165MPa, to prevent the pressure inside too high, so that the
utilization would be safe.
- The gauge displays the
pressure figures and temperature figures
which could be more suitable for watching and operating.
- Good sealing.
Temperature rises quickly and power consumes less.
- The highest temperature
could reach to 126-128≧
|
|
|
Application:
This kind of portable electric pressurized
steam sterilizer is suitable for various kinds of areas such as Medical
treatment, scientific research and food industry. It is used to
sterilize the medical equipment, surgical dressings, glass utensils,
surgical operating instruments, laboratory glasses instruments,
rubber products, foodstuff, etc.
|
|
Notes:
- Attention the location of water
level to avoid the electric heating tube of damaging.
- Categories the various subjects to
sterilize in different time.
- Check the pressure gauge often.
When the pressure gauge could not back to ZERO or the gauge could
read the exactly the figure, fix it in time and change the gauge.
- When the machine works, the
operating people should not leave the machine to prevent danger.
|
|
Using Method:
- Filling Water: Filling the water
to over the electric heating tube (about 3L water).
- Sealing: Put the subjects which
need sterilizing in the machine in order, then capping the machine,
put the soft pipe in the bottle. Aligning the up and down card slot,
screw tight of the butterfly style screw.
- Heating: When heating begins,
first put the deflating valve to the vertical location to overflow
the cool air, when steam erupts, put the deflating valve to the
normal place. calculate the time when the sterilizing pressure reach
its own areas.
- Drying: After heating, the
sterilized instruments needs drying. So first deflate the air steam,
then heating for 1-2 minutes until the air pressure gauge indicates
ZERO, after that, open the capper and keep heating for another 10
minutes.
|
|
Item# |
Description |
QTY |
Unit |
Note |
160629 |
8L Electric Pressurized
Steam Sterilizer 220V |
|
|
|
|