Digital Coating Thickness Gauge Meter Tester

General information

The DT-156 coating thickness gauges work either on the magnetic induction principle

or on the eddy current principle,depending on the type of probe used. 

You can select the type of probe via MENU system, or it will be work automatically.

The gauges conform to the following industrial standards:

GB/T 4956-1985

GB/T 4957-1985

JB/T 8393-1996

JJG 889-95

JJG 818-93

 

Features

Measured Coatings: Non-magnetic coating (e.g. Paint, zinc) on steel; 

Insulating coatings (e.g. Paint, anodizing coatings) on no-ferrous metals

Operating with MENU easily

Two measuring mode: CONTINUE and SINGLE mode

Two working mode: DIRECT and GROUP mode (4groups)

Statistic Display: AVG, MAX, MIN, NO., S.DEV

One point calibrating and two points calibrating independently for each working mode

Zero calibrating easily

Memory for 320 readings(80 for each group)

Delete single readings and all group readings easily

High alarm and Low alarm for all working mode

Low battery, error indication

USB interface for PC analysis software

Disable Auto-Power-off function via MENU setting.

 

Application

1.This compact and handy gauge is designed for nondestructive, fast and precise

coating thickness measurement.The principal applications lie in the field of corrosion 

protection.It is ideal for manufactures and their customers,for offices and specialist advisers, 

for paint shops and electroplaters, for the chemical, automobile, shipbuilding and aircraft industries and for light and heavy engineering.

2.DT-156 gauges are suitable for laboratory, workshop and outdoor use.

3.The probe can work on both principles, magnetic induction and on the eddy 

current principle. One probe only is required for coating measurement both on ferrous 

and non-ferrous metal substrates. It is adaptable to specific tasks: i.e.

They can be used on special geometries or on materials with special properties.

¡¡

Note

Requires 2 AAA batteries, batteries are not included

Specifications

SENSOR PROBE

F

NF

Working Principle Magnetic induction Eddy current
Measuring Range

 

0 ~ 1250µm 0 ~ 1250µm
0 ~ 49.21mils 0~49.21mils
Guaranteed Tolerance (of reading)

 

0 ~ 850µm (¡À3%+1µm);  850 ~ 1250µm(¡À5%)
0 ~ 33.46mils (¡À3%+0.039mils); 33.46 ~ 49.21mils (¡À5%)
Accuracy / Precision

 

0 ~ 50µm (0.1µm);  50 ~ 850µm (1µm);  850 ~ 1250µm (0.01mm)
0 ~ 1.968mils (0.001mils);  1.968 ~ 33.46mils (0.01mils);33.46 ~ 49.21(0.1mils)
Min. Curvature Radius 1.5mm 3mm
Diameter of Min. Area 7mm 5mm
Min. Substrate Thickness 0.5mm 0.3mm
Low Range Precision 0.1µm 0.1µm
Working Temperature 0 ~ 40¡ãC  (32 ~ 104¡ãF)
Working Relative Humidity 20 ~ 90%RH
Size 110 x 50 x 23mm
Weight 100g

¡¡

¡¡

Item Included

Digital Coating Thickness Gauge Meter Tester(220123)

Item Number Description QTY Unit Note
220123

Digital Coating Thickness

  Gauge Meter Tester

1 set ¡¡