Low Temperature Cooling Liquid Circulator 6L |
|||
![]() |
|||
Introduction | |||
DC series low temperature constant temperature tank is controlled by single chip microprocessor, self-tuning PID adjustment, imported temperature sensor temperature measurement, high temperature control accuracy, low volatility; high quality famous brand compressor (some models are all imported compressors or compressors), high refrigeration efficiency, fast cooling and low noise. The instrument is stable and reliable, and the operation is convenient and safe. |
|||
Features | |||
1. The machine adopts microcomputer based temperature control. High accuracy of temperature control. |
|||
Parameters | |||
Model | DC0506W | ||
Voltage | 110V | ||
Power | 1500W | ||
Volume | 6L | ||
temperature fluctuation | ±0.03 ℃(Water or pure ethanol) | ||
Temperature range | -5℃-100℃ | ||
resolution ratio | 0.01 ℃ | ||
Opening Size | 145×145×150mm(long and wide and deep) | ||
pumping flow | 8 L/min | ||
Pump circulation mode | output loop | ||
Instruction | |||
1.Remove the package, do a good job of cleaning, put on the solid worktable. |
|||
Environmental requirements | |||
1. The thermostatic bath shall be placed on a solid working table. 2. No vibration and no harmful gas. 3. Ambient temperature should be less than 30°C and relatively stable, cannot be high and low, affect the temperature control accuracy. 4. The ambient humidity should be less than 80% and the humidity is too high. When the constant temperature tank is working at low temperature, the compressor may dewing. |
|||
Precautions for Use | |||
1. Before use, it must be confirmed that the liquid medium has been added to the tank body, and the distance between the liquid level of the medium and the working table should be less than 3 cm, otherwise the heater may dry burn and damage when electrified.。 2. The selection of liquid media in the tank shall conform to the following principles: ⑴When the working temperature is lower than 5 ℃, absolute ethyl alcohol or ethylene glycol is used for the liquid medium. ⑵When the working temperature is 5 ℃ ~95 ℃, water is generally used in liquid medium. ⑶When the working temperature is between 95 and 100 ℃ , a 15% aqueous glycerol solution can be used for the liquid medium. Note: The operating temperature here is the temperature to which the liquid medium in the tank is to be reached; 3. Power supply:110V, the power of the power supply shall be greater than the total power of the instrument, and the power supply must have good "ground" device; 4. Because the refrigeration compressor works continuously (refrigerator, air conditioning is intermittent), it needs to be shut down for a day after a long period of continuous work (such as about 5 days). 5. The instrument should be placed in a dry and ventilated place, and there are no obstacles in the 300mm around the instrument. 6. When the working temperature of the thermostatic bath is lower or higher, care should be taken not to open the upper cover, and do not enter the tank to prevent frostbite or scald. 7. After the use, all the switches are put in the closed state and the power is cut off. 8. The instrument should do a good job of regular cleaning and keep the working table and operation panel clean and tidy. 9. Pay attention to the level of the liquid level in the observation tank. When the liquid level is too low, the liquid medium shall be added in time. |
|||
Display | |||
Item Number:020462 | |||