10L -30℃ Laboratory Chiller Circulator |
Low temperature coolant circulation pump is a low-temperature liquid circulation equipment that adopts mechanical refrigeration, and has the function of providing low-temperature liquid and low-temperature water bath. Combining rotary evaporators, vacuum freeze-drying boxes, circulating water vacuum pumps, magnetic stirrers and other instruments, perform multifunctional chemical reaction operations and drug storage at low temperatures. |
Parameters |
Storage capacity: 10L Minimum no-load temperature: -30 ℃ Flow rate: 35L/min Lift: 4-6 meters Constant temperature accuracy: ± 2 ℃ Power supply: 110V60Hz Power: 880W Working humidity: 60-80% ventilation External dimensions: 42*54.5*121.5cm Pipe length: 2M*2 |
Product features |
1. Large area heat dissipation window effectively protects the
operation of the compressor and can work for a long time. 2. Universal wheel design, not limited by site, can move freely. 3. Control panel: PID intelligent temperature control module, LCD digital display. 4. The spiral design refrigerant circulation pipe has a large contact area and high work efficiency. 5.304 stainless steel, electrostatic spraying, rust, and corrosion resistance. |
Precautions for use |
1.Before using the
low-temperature coolant circulation pump, liquid medium
(ethanol is recommended) should be added to the tank. The liquid level of the
medium should not exceed the cooling coil in the tank and
should be 20mm lower than the workbench.
2. Avoid acidic or alkaline
substances entering the tank to corrode the coil and inner
liner.
3. The instrument should be
placed in a dry and ventilated place, with no obstacles
within 300mm around the instrument;
4. Regularly observe the
liquid level in the tank. When the liquid level is too
low, liquid medium should be added in a timely manner
5. When the working
temperature of the low-temperature coolant circulation pump
is low, attention should be paid not to open the upper
cover, and hands should not enter the tank to prevent
frostbite;
6. After use, all switches
should be turned off and the power should be cut off;
7. When circulating liquid
externally, customers should pay special attention to the
firmness of the connection of the outlet pipe to prevent
detachment and prevent liquid leakage.
8. The instrument should be
regularly cleaned and not used for a long time. The medium in the slot should
be emptied and wiped clean to keep the workbench and
operating panel clean.
|
Packaging List |
Low temperature coolant circulation pump * 1 Stainless steel bracket * 1 Water pipe * 2 Faucet * 1 Sealing tape * 1 |
Item Number: 10L -30℃ Laboratory Chiller Circulator (220630) |
You can make
order with no worry. Any concern just feel free to let us know, we'll reply in 24 hours in normal condition. Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays. Warranty: 6 months' warranty for the machines, not for the consumables. We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost. |
|