5L -40℃ Low temperature coolant circulation pump |
Low temperature coolant circulation pump is a low-temperature liquid circulation equipment that adopts mechanical refrigeration, and has the function of providing low-temperature liquid and low-temperature water bath. Combining rotary evaporators, vacuum freeze-drying boxes, circulating water vacuum pumps, magnetic stirrers and other instruments, perform multifunctional chemical reaction operations and drug storage at low temperatures. |
Parameters |
Storage capacity: 5L Minimum no-load temperature: -40 ℃ Flow rate: 35L/min Lift: 4-6 meters Constant temperature accuracy: ± 2 ℃ Power supply: 110V60Hz Power: 630W Working humidity: 60-80% ventilation External dimensions: 51 * 35 * 115.5cm Pipe length: 2M*2 |
Product features |
1. Large area heat dissipation window effectively protects the
operation of the compressor and can work for a long time. 2. Universal wheel design, not limited by site, can move freely. 3. Control panel: PID intelligent temperature control module, LCD digital display. 4. The spiral design refrigerant circulation pipe has a large contact area and high work efficiency. 5.304 stainless steel, electrostatic spraying, rust, and corrosion resistance. |
Precautions for use |
Before using the low-temperature coolant circulation pump,
liquid medium (ethanol is recommended) should be added to the
tank. The liquid level of the medium should not exceed the
cooling coil in the tank and should be 20mm lower than the
workbench. 2. Avoid acidic or alkaline substances entering the tank to corrode the coil and inner liner. 3. The instrument should be placed in a dry and ventilated place, with no obstacles within 300mm around the instrument; 4. Regularly observe the liquid level in the tank. When the liquid level is too low, liquid medium should be added in a timely manner 5. When the working temperature of the low-temperature coolant circulation pump is low, attention should be paid not to open the upper cover, and hands should not enter the tank to prevent frostbite; 6. After use, all switches should be turned off and the power should be cut off; 7. When circulating liquid externally, customers should pay special attention to the firmness of the connection of the outlet pipe to prevent detachment and prevent liquid leakage. 8. The instrument should be regularly cleaned and not used for a long time. The medium in the slot should be emptied and wiped clean to keep the workbench and operating panel clean. |
Packaging List |
Low temperature coolant circulation pump * 1 Stainless steel bracket * 1 Water pipe * 2 Faucet * 1 Sealing tape * 1 |
|
Item Number: 220631 |