新建网页 1 新建网页 1

Electric Hydraulic Pump

Technical Parameters:
Model GYB-700AⅢ
Function Solenoid  valve
Rated Pressure 70Mpa
Oil Flow 3.5L/min;1400r/min
Control Foot Switch/Hand Switch
Voltage 110V/60Hz 750W
Oil Capacity 8L

Specification:
Should be used first quick connector quick connector sets equippedwith hydraulic equipment connected. When plugged in, press thepower switch to operate for some time, in the absence of pressure,the output hydraulic oil all the work, and the output hydraulic oil withincreasing load all the work up to 70Mpa, the need to buck their ownsupercharged, press the solenoid valve switch the pressure back tozero and hydraulic equipment, hydraulic oil back to the fuel tank.Remove the quick connector sets the end, unplug the power.
Pictures:
Usage:
Before using the pump,check the oil tank of the pump,make sure there has enough oil in the oil tank and higher than the oil-window.

1.Open the air-out screw before operating the pump;

2.Inspect the oil pressure by the gauge;

3.Change the hydraulic oil every 18 months;

4.Filter the oil before changing the oil,#10 hydraulic oil is recommended;

5.Handle the pump at 10-50℃;

6.Stop working once the motor is hotter to a higher temperature to protect the whole pump system;

7.Keeping replacing the oil hose once any damaged or aging,the standard rated pressure of oil hose is 70Mpa;

8.Replace the bearing and lubricate them according every 18 months.

Common faults and solutions:
Faults Reason Solutions
Motor Abnormal Electric power Check the power
Pressure Abnormal Oil leaking Make inspection and replce the new O-rings
Oil flow insufficient Oil Add oil or change hydraulic oil
Item Included:
  Item Number Unit Quantity Item Include
230026 Set 1 1 Set of Electric Hydraulic Pump